ALOCK Elevator Control Model Smart Louncher

قابلیت های اصلی:

سایر مدل ها:

EMPTY

Elevators are among the most widely used equipment in hotel projects. Controlling these devices is one of the most difficult tasks for hoteliers. The ALOCK collection solves this problem with the latest technologies in the world. ALOCK elevator control devices are known as elevator controllers. These devices are able to control people's access and traffic. The LOCNCHER Switch Class ALOCK Smart Elevator Controllers work like this:

Once installed inside the elevator car, it is programmed with a computer and encoder, and only room card holders with valid credit time will be able to use the elevator. This means that holders of room cards will only be able to choose their floor after placing their room card in front of the device and will not be able to select other floors except the public floors. If their stay expires, they will no longer be able to use the elevator. Of course, this device works to identify licensed people at three levels:
1. Only Mifare 13.56 frequency card holders will be able to use the elevator.
2. Only holders of hotel cards of the same project are able to use the elevator without considering the time validity of the card.
3. Only people who have a booked room and a room credit card are able to use the ascension sensor.

How to identify the card will depend on the request of the buyers and will be planned accordingly. Users who have a valid credit card will be able to choose the desired floor after entering the elevator car and placing the card in front of the device. In this system, everyone in the elevator car has to put their room card in front of the device to go to the desired floor. This device is able to transfer users to the same selected class by recognizing the room and floor number defined on the card.

Public floors such as parking, lobby, restaurant, coffee shop, commercial, swimming pool, etc. are known as public floors and anyone who is in the elevator car will be able to access these floors without the need for a card.

One device is required for every 8 floors. This device is installed in the elevator COP panel.

بیشتر بخوانید
0
100 $
گالری ویدئو
امکانات آفلاین
امکانات آنلاین
Specifications
Model
Elevator Controller
Class
Louncher
dimensions of the device
20cm * 15cm
Dimensions of card reader
4cm * 7cm
input voltage
12V DC
Amp current
1000mA
Card type
Temic T5557 125Khz or Mifare 13.56 Mhz
Computer programming capability
Communication technology
Offline (Stand alone)
The number of floors that can be used for each device
8 floors
Thermal range of device operation
-30 to +70
Maximum device performance humidity
Up to 98%
Warranty period
2 years from the date of sale
After-sales service
10 years after the sale date